HEX
Server: Apache
System: Linux host11.registrar-servers.com 4.18.0-553.lve.el8.x86_64 #1 SMP Mon May 27 15:27:34 UTC 2024 x86_64
User: robovet (12567)
PHP: 7.2.34
Disabled: NONE
Upload Files
File: /home/robovet/mail/new/1721126937.M859609P636238.host11.registrar-servers.com,S=6132,W=6241
Return-Path: <>
Delivered-To: [email protected]
Received: from host11.registrar-servers.com
	by host11.registrar-servers.com with LMTP
	id 4JyMMhlQlmZOtQkAMOv5Ig
	(envelope-from <>)
	for <[email protected]>; Tue, 16 Jul 2024 06:48:57 -0400
Return-path: <>
Envelope-to: [email protected]
Delivery-date: Tue, 16 Jul 2024 06:48:57 -0400
Received: from mailnull by host11.registrar-servers.com with local (Exim 4.96.2)
	id 1sTfjt-002q8b-2f
	for [email protected];
	Tue, 16 Jul 2024 06:48:57 -0400
X-Failed-Recipients: [email protected]
Auto-Submitted: auto-replied
From: Mail Delivery System <[email protected]>
To: [email protected]
References: <[email protected]>
Content-Type: multipart/report; report-type=delivery-status; boundary=1721126937-eximdsn-1193303959
MIME-Version: 1.0
Subject: Mail delivery failed: returning message to sender
Message-Id: <[email protected]>
Date: Tue, 16 Jul 2024 06:48:57 -0400

--1721126937-eximdsn-1193303959
Content-type: text/plain; charset=us-ascii

This message was created automatically by mail delivery software.

A message that you sent could not be delivered to one or more of its
recipients. This is a permanent error. The following address(es) failed:

  [email protected]
    No Such User Here

--1721126937-eximdsn-1193303959
Content-type: message/delivery-status

Reporting-MTA: dns; host11.registrar-servers.com

Action: failed
Final-Recipient: rfc822;[email protected]
Status: 5.0.0

--1721126937-eximdsn-1193303959
Content-type: message/rfc822

Return-path: <[email protected]>
Received: from robovet by host11.registrar-servers.com with local (Exim 4.96.2)
	(envelope-from <[email protected]>)
	id 1sTfjt-002q7Y-1q
	for [email protected];
	Tue, 16 Jul 2024 06:48:57 -0400
To: [email protected]
Subject: =?us-ascii?Q?Robovet__"Revolutionize_Your_Maintenance_Routin?=  =?us-ascii?Q?e_with_Balanset-1A"?=
X-PHP-Script: www.robovet.com/index.php for 95.216.233.128, 95.216.233.128, 95.216.233.128
X-PHP-Filename: /home/robovet/public_html/index.php REMOTE_ADDR: 95.216.233.128
Date: Tue, 16 Jul 2024 10:48:57 +0000
From: Robovet <[email protected]>
Reply-To: [email protected]
Message-ID: <[email protected]>
X-Mailer: PHPMailer 6.5.0 (https://github.com/PHPMailer/PHPMailer)
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Sender:  <[email protected]>

From: DanielElope <[email protected]>
Subject: Revolutionize Your Maintenance Routine with Balanset-1A

Message Body:
The Balanset-1A unit (hereinafter referred to as "the Device")  is a portable kit designed for balancing rotors operating in their own bearings. This device allows for balancing in one or two planes, significantly increasing the service life of machines and mechanisms by reducing dynamic loads on bearing units. The kit includes two vibration sensors, a phase angle sensor, and a measuring unit. 
 
Features and Applications 
 
 On-site balancing: The device enables the rotor to be balanced directly in its bearings, eliminating the need for special machines and mechanism disassembly. This simplifies the process and saves time.  
 
 Automated procedure: The entire balancing process, from measurement to the installation of corrective weights, is conducted automatically. The user does not need additional skills beyond what is provided in the instructions.  
 
 Results archiving: All balancing results are saved in the Balancing Archive and can be printed as protocols if needed.  
 
 Additional functions: The Balanset-1A device can also be used as a regular vibrometer to measure the root mean square (RMS) value of total vibration, the RMS value of the rotational component of vibration, and the rotational speed of the rotor. Additionally, it displays vibration velocity time function and spectrum graphs, which can be useful for assessing the technical condition of the balanced machine.  
 
Package Contents and Operating Principle 
 
 The complete package includes a measuring unit, two vibration sensors, a phase angle sensor, the necessary accessories, and a flash drive with software. The device operates based on the measurement of mechanical vibrations. Vibration sensors convert the vibrations into an electrical signal, which is then processed by the measuring unit and transferred to a computer for further processing and analysis.  
 
Balancing Recommendations. <a href=https://vibromera.eu/example/balancing-instrument-at-the-price-of-a-vibrometer/> Vibrometer </a> mode 
 
 Machine condition: Balancing should only be performed on mechanisms that are in good technical condition and securely mounted on their foundations. It is not recommended to balance mechanisms with worn or damaged bearings.  
 
 Rotor cleaning: Before starting work, the rotor should be cleaned of any contaminants.  
 
 Resonance detection: If measurement results differ significantly from run to run, this may indicate resonance. In this case, the rotational speed should be changed or the installation conditions on the foundation should be altered.  
 
 Vibrometer measurements: Preliminary measurements in vibrometer mode are recommended. If the total vibration value matches the rotational component, the rotor imbalance is the main contributor to vibration, and balancing can proceed.  
 
 
 Manual static imbalance check: For rotors with horizontal shafts, static imbalance can be checked manually by rotating the rotor 90 degrees. If imbalance is detected, a balancing weight should be installed.  
 
Conclusion 
 
 Utilizing the Balanset-1A device enables effective and quick rotor balancing, enhancing their performance and extending their service life. This is a versatile solution for those involved in the maintenance and repair of rotating mechanisms.

-- 